Offshorecable summary - Power Cables 250V/0,6/1/1,2kV.

Hopefully this list will be usefully in you daily search after resources within the Offshore / Marina /Ex / Hazardous field.

 

Power cable - Fire resistant, flame retardant BFOU / BU

BFOU 0,6/1(1,2)kV. P5/P12

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour/screen: (O) Tinned annealed copper wire braid
  • Tape over armour/screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX (Zone 0,1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • For installation in areas exposed to MUD and drilling/cleaing fluids.
  • Meets the MUD resistance requirement in NEK TS 606:2009

BFOU 0.6 11.2kV P5 P12

BFOU 0,6/1kV. P5/P12 Artic Grade

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour/screen: (O) Tinned annealed copper wire braid
  • Tape over armour/screen: Rubberized Polyamide tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX (Zone 0,1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • For installation in areas exposed to MUD and drilling/cleaning fluids.
  • Meets the MUD resistance requirement in NEK TS 606:2009
  • Meets the cold bend / cold impact requirements in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at 40°C / -35°C.

BFOU 0.6 11.2kV P5 P12 Arctic Grade

BFOU 0,6/1kV P34 / 1100°C / 30-60 minutes

  • Power Cable Fixed Installation.
  • Conductor: Tinned stranded circular copper , IEC 60228 Class 2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour/screen: (O) Tinned copper wire braid
  • Tape over armour/screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • HFC protection: (-HFC) Extruded heatblock compound
  • Tape: Lapped glassfibre tape
  • Overall sheath: Flame retardant, halogen-fre thermoplastic compound, SHF1 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both Ex- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

BFOU HCF 0.6 11.2kV P34 Hydrocarbon Fire

BFOU-JF 0,6/1kV / 250kW /m² / 1200°C

  • Power Cable Fixed Installation.
  • Conductor: Tinned stranded circular copper, IEC 60228 Class 2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour/screen: (O) Tinned copper wire braid / PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • JF protection: (-JF) Extruded heatblock compound
  • Tape: Lapped glassfibre tape
  • Overall sheath: Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX (Zone 0,1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance vital.
  • Jet Fire protection and resistant, flame retardant halogen-free power cable.
  • Rated and certified by; Det Norske Veritas for withstanding 30 minutes.

BFOU JF 0.6 1kV Jet Fire

BFOU-VFD 0,6/1(1,8/3)kV, braid as earth core

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC) , IEC 60228 Class 2
  • Insulation: (B) 3 layers of Mica-tape + EP-rubber, IEC 60092-351 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour/screen: (O) Cu/PET tape, Tinned annealed copper wire braid Shield coverage is 100%
  • Tape over armour/screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)
  • Outer sheath colour: Black

Application/ Use:

  • Special cable for Variable Frequency Drives / Azimuth motors.
  • Suitable for voltage peaks up to 3000V.
  • For installation in areas exposed to MUD and drilling / cleaning fluids.
  • Meets the MUD resistance requirement in NEK TS 606:2009.

BFOU VFD 0.6 11.8 3kV Class 2 Variable Frequency Drives

BFOV 0,6/1kV, resistant to turbine and hydraulic oils

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour/screen: (O) Tinned annealed copper wire braid.
  • Tape over armour / screen: PET tape
  • Outer sheath: (V) Flame retardant, halogen-free and oil resistant thermoset compound (Therban), SHF2 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Especially resistent to the following hydraulic oils:
    • HydraWay HVXA 46
    • Nyco Turbonycoil 600
    • Nyco Turbonycoil 610
    • Mobile Glygoyle 11
    • Turbway 32

BFOV 1kV

BU 0,6/1(1,2kV P17 Power cable, Unarmoured

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: No inner covering. (Additional tapes may be applied.
  • Armour/screen: No armour.
  • Outer sheath: (U) Flame retardant, halogen-free and MUD resistant thermoset compound (Therban), SHF2 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in safe areas, emergency and critical systems where requirement for fire resistance exists.
  • For installation in areas exposed to MUD and drilling fluids.
  • Meets the MUD resistance requirement in NEK TS 606:2009.
  • These cables are double insulated and Single core cables are used as battery cables.

BU 0.6 11.2kV P17

Power cable - Flame retardant RFOU / RU

RFOU 0,6/1(1,2)kV P1/P8 Power cable

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoset compound
  • Tape over inner covering: PET-tape
  • Armour/screen: (O) Tinned annealed copper wire braid
  • Tape over armour/screen: PET-tape
  • Outer sheath: (U) Flame retardant, halogen-free and MUD resistant thermoset compound , SHF2 (IEC 60092-360)
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX (Zone 0,1 & 2)- and safe areas, general purposes.
  • For installation in areas exposed to MUD and drilling/cleaning fluids.
  • Meet the MUD resistance requirement in NEK TS 606:2009.

RFOU 0.6 11.2kV P1 P8

RFOU 0,6/1kV P1/P8 Artic Grade

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: (F) Flame retardant and halogen-free thermoset compound
  • Tape over inner covering: PET-tape
  • Armour/screen: (O) Tinned annealed copper wire braid
  • Tape over armour/screen: Rubberized Polyamide tape
  • Outer sheath: (U) Flame retardant, halogen-free mud and cold bend / cold impact resistant thermoset compound, SHF2, IEC 60092-359
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX- and safe areas, general purposes.
  • For installation in areas exposed to MUD and drilling/cleaning fluids.
  • Meet the OIL & MUD resistance requirement in NEK 606.
  • Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at -40°C /-35°C.

RFOU 0.6 11.2kV P1 P8 Arctic Grade

RFOU-VFD 0,6/1(1,8/3)kV, braid as earth core

  • Power Cable Fixed Installation.
  • Conductor: Tinned stranded circular copper, IEC 60228 Class 2 (1)
  • Insulation: (R) EP-rubber (2)
  • Inner covering: (F) Flame retardant and halogen-free thermoset compound (3)
  • Armour/screen: (O) Cu/PET-tape (4), Tinned copper wire braid (5), PET-tape (6), Shield coverage is 100%
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2. (7)
  • Outer sheath colour: Black or Yellow

Application/ Use:

  • Special cable for Variable Frequency Drives / Azimuth motors up to 1kV.
  • Suitable for voltage peaks up to 3600V.
  • Armoured cable for fixed installations in ship and offshore units.
  • Can be installed and operated both indoors and outdoors.
  • Oil and MUD resistant to NEK 606.

RFOU VFD Class2

RFOU-VFD 0,6/1(1,8/3)kV with seperate earth cores

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed, flexible copper, IEC 60228 Class 5
  • Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
  • Lay up: 3 insulated phase-conductors are laid up with 3 insulated earth conductors
  • Inner covering: (F) Flame retardant and halogen-free thermoset compound
  • Armour/screen: (O) Cu/PET-tape, Tinned copper wire braid, Shield coverage i 100%
  • Outer sheath: (U) Flame retardant, halogen-free thermoset compound, SHF2, IEC 60092-360
  • Outer sheath colour: Black or Yellow

Application/ Use:

  • Special cable for Variable Frequency Drives / Azimuth motors up to 1kV.
  • Suitable for voltage peaks up to 3600V.
  • Armoured cable for fixed installations in ship and offshore units.
  • Can be installed and operated both indoor and outdoors.
  • Oil and MUD resitant to NEK 606.

RFOU VFD Class5

RU 0,6/1(1,2)kV P18 Power cable, Unarmoured

  • Power Cable Fixed Installation.
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class 2
  • Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
  • Lay up / Shielding: Cores laid up in concentric layers
  • Inner covering: No inner covering. (Additional tapes may be applied)
  • Armour/screen: Nor armour
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2, IEC 60092-360
  • Outer sheath colour: Black

Application/ Use:

  • Fixed installation for power, control and lighting in both EX- and safe areas, general purposes.
  • For installation in areas exposed to MUD and drilling/cleaning fluids.
  • Meet the OIL & MUD resistance requirement in NEK TS 606:2009.
  • These cables are double-insulated and Single core cables are used as battery cables.

RU 0.6 11.2kV P18

Other cables - RU (Earthing) IFLI P16 Living quarter/Office

UX 1000V P15 Earthing wire

  • Power Cable Fixed Installation.
  • Conductor: Tinned, stranded copper, IEC 60228 class 2
  • Insulation: (U) Flame retardant halogen-free thermoset compound, HF90, IEC 60092-360
  • Unsheated: (X)
  • Outer sheath colour: Yellow/green

Application/ Use:

  • Insulated conductor for earthing and bonding services.
  • MUD resistant in accordance with NEK TS 606:2009.

UX 1000V P15

IFLI 250V P16

  • Power Cable Fixed Installation.
  • Conductor: Annealed stranded copper
  • Insulation: (I) Cross linked Polyethylene (XLPE)
  • Inner sheath: (F) Flame retardant halogen-free thermoplastic compound.
  • Earth conductor: Stranded copper conductor
  • Metallic sheath: (L) Aluminium tape (Longitudinal)
  • Sheath: (I) Flame retardant halogen-free thermoplastic compound.
  • Outer sheath colour: Grey

Application/ Use:

  • Cable for living quarter and office areas.
  • Halogen-free, NEK 606

IFLI 250V P16

Reservation:

But be aware - this site - ex-products.eu, and its owner / webmaster can not be held responsible for any faults, information or any thinkable according to this lists.

It is the user's responsibility to ascertain if a particular product is safe and without risk to health and safety by virtue of its location in a hazardous area, i.e. classification of zones, gas groups, ignition temperatures, etc. Both the specifier and user should be thoroughly familiar with standard mentioned on this sites or any document within.

Whilst every care has been taken in the compilation of this document, we regrets that it cannot accept responsibility for any errors or omissions contained herein. Readers should not rely upon the information contained in this document or site without seeking specific safety advice and ensuring that their own particular circumstances are in accordance with the matters set out.

Utvalgte artikler

Husk at også innbruddstyver sjekker Facebook.

5 spørsmål og svar/råd.

Hva bør du gjøre når du skal reise bort?

Les mer …

Noen søketips.

Standardsøk, Katalogsøk.

Vi vil i denne oversikten, etterhvert som vi blir kjent med det, legge inn opplysninger som kan gjøre det litt lettere å søke etter linker, leverandører osv.. 

Les mer …

Utvalgte linker

Nyeste linker

Populære linker

Infoklikk.no

Hjelper deg med å finne ressurser.

Dagens dato:

Infoklikk.no kan ikke på noen måte gjøres ansvarlig for innholdet på eksterne nettsteder som er linket på eller til Infoklikk.no sine sider. / Infoklikk.no - can not be held responsible for any content on any external website linked on or to the Infoklikk.no website.