Hopefully this list will be usefully in you daily search after resources within the Offshore / Marina /Ex / Hazardous field.

 

Instrumentation Cables - BU /BFOU - Collective Screen

BU(c) 150/250 (300)V S14 Unarmoured

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Inner covering: No inner covering. (Additional tapes may be applied)
  • Armour / screen: Nor armour.
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meets the mud resistant requirements in NEK TS 606:2009.

BUc 150 250300V S14

BFOU(c) 150/250 (300)V S4/S8

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circualr copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET-tape
  • Armour / screen: (O) Tinned annealed copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX-(Zone 0, 1 & 2) and safe areas, emergency and critical systems whre requirement for fire resistance exists.
  • Meets the mud resistant requirements in NEK TS 606:2009

BFOUc 150 250300V S4 S8

BFOU(c) 150/250 (300)V S4/S8 Arctic Grade

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-351 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET-tape
  • Armour / screen: (O) Tinned annealed copper wire braid
  • Tape over armour / screen: PET-tape
  • Outer sheath: (U) Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-359)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meet the OIL & MUD resistance requirement in NEK TS 606:2009.
  • Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at -40°C / -35°C.

BFOUc 150 250300V S4 S8 Arctic Grade

BFOU-HCF(c) 250V S16 / 1100°C / 30 minutes

  • Instrumentation Cable
  • Conductor: Tinned stranded circular copper, IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour / screen: (O) Tinned copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • HFC protection: -HFC Extruded heatblock compound
  • Tape: Lapped glassfibre tape
  • Overall sheath: Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360)
  • Outer sheath colour: Grey, Blue or Black

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.

BFOU HCF c 250V S16 Hydrocarbon Fire

BFOU-XFR(c) 150/250 (300)V / Mud resistant

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour / screen: (O) Tinned annealed copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meets the mud resistant requirements in NEK TS 606:2009.
  • Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes).

BFOU XFRc 150 250300V Extended Fire Resistant

Instrumentation Cables - BU /BFOU - Induvidual Screen

BU(i) 150/250 (300)V S13 Unarmoured

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbers printed directly on the insulated conductors.
  • Lay up / Shielding: Individually shielded pairs / triples / quads are laid up in concentric layers and wrapped with a PETP tape.
  • Inner covering: No inner covering. (Additional tapes may be applied)
  • Armour / screen: No armour.
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, control and alarm systems in both EX- (Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meets the mud resistant requirements in NEK TS 606:2009.

BUi 150 250300V S13

BFOU(i) 150/250 (300)V S3/S7

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Lay up / Shielding: Individually shielded pairs / triples / quads are laid up in concentric layers and wrapped with PETP tape.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour / screen: (O) Tinned annealed copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 0, 1 & 2) and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meets the mud resistant requirements in NEK TS 606:2009.

BFOUi 150 250300V S3 S7

BFOU(i) 150/250V (300)V S3/S7 Arctic Grade

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-351 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Lay up / Shielding: Individually shielded pairs / triples / quads are laid up in concentric layers and wrapped with a PETP tape.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour / screen: (O) Tinned annealed copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-359)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meets the OIL & MUD resistance requirement in NEK TS 606:2009.
  • Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at -40°C / -35°C.

BFOU i S3 S7 Artic grade

BFOU-HCF(i) 250V S15 / 1100°C / 30 minutes

  • Instrumentation Cable
  • Conductor: Tinned stranded circular copper, IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triples is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour / screen: (O) Tinned copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • HFC protection: -HFC Extruded heatblock compound
  • Tape: Lapped glassfibre tape
  • Overall sheath: Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360)
  • Outer sheath colour: Grey, Blue or Black

 

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.

BFOU HCF i 250V

BFOU-XFR(i) 150/250 (300)V / Mud resistant

  • Instrumentation Cable
  • Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
  • Insulation: (B) Mica-tape + EP-rubber, IEC 60092-360 (EPR)
  • Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triples is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  • Lay up / Shielding: Individually shielded pairs / triples / quads are laid up in concentric layers and wrapped with a PETP tape.
  • Inner covering: (F) Flame retardant and halogen-free thermoplastic compound
  • Tape over inner covering: PET tape
  • Armour / screen: (O) Tinned annealed copper wire braid
  • Tape over armour / screen: PET tape
  • Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
  • Outer sheath colour: Grey or Blue

Application/ Use:

  • Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists.
  • Meets the mud resistant requirements in NEK TS 606:2009.
  • Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes).

BFOU XFRi 150 250300V Extended Fire Resistant

 

Reservation:

 

But be aware - this site - ex-products.eu, and its owner / webmaster can not be held responsible for any faults, information or any thinkable according to this lists.

It is the user's responsibility to ascertain if a particular product is safe and without risk to health and safety by virtue of its location in a hazardous area, i.e. classification of zones, gas groups, ignition temperatures, etc. Both the specifier and user should be thoroughly familiar with standard mentioned on this sites or any document within.

Whilst every care has been taken in the compilation of this document, we regrets that it cannot accept responsibility for any errors or omissions contained herein. Readers should not rely upon the information contained in this document or site without seeking specific safety advice and ensuring that their own particular circumstances are in accordance with the matters set out.

Utvalgte artikler

Husk at også innbruddstyver sjekker Facebook.

5 spørsmål og svar/råd.

Hva bør du gjøre når du skal reise bort?

Les mer …

Noen søketips.

Standardsøk, Katalogsøk.

Vi vil i denne oversikten, etterhvert som vi blir kjent med det, legge inn opplysninger som kan gjøre det litt lettere å søke etter linker, leverandører osv.. 

Les mer …

Utvalgte linker

Nyeste linker

Populære linker

Infoklikk.no

Hjelper deg med å finne ressurser.

Dagens dato:

Infoklikk.no kan ikke på noen måte gjøres ansvarlig for innholdet på eksterne nettsteder som er linket på eller til Infoklikk.no sine sider. / Infoklikk.no - can not be held responsible for any content on any external website linked on or to the Infoklikk.no website.