Instrumentation Cables - RU / RFOU - Collective shielded
|
RU(c) 150/250 (300)V S12 Unarmoured
- Instrumentation Cable
- Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
- Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
- Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / Triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
- Inner covering: No inner covering. (Additional tapes may be applied)
- Armour / screen: No armour.
- Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
- Outer sheath colour: Grey or Blue
|
Application/ Use:
- Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas.
- Meets the mud resistant requirements in NEK TS 606:2009.
|
RFOU(c) 150/250 (300)V S2/S6
- Instrumentation Cable
- Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
- Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
- Pair / Triple / Qad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / Triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
- Inner covering: (F) Flame retardant and halogen-free thermoset compound
- Tape over inner covering: PET-tape
- Armour / screen: (O) Tinned annealed copper wire braid
- Tape over armour / screen: PET-tape
- Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
- Outer sheath colour: Grey or Blue
|
Application/ Use:
- Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 0,1 & 2) and safe areas.
- Meets the mud resistant requirements in NEK TS 606:2009.
|
RFOU(c) 250V S2/S6 Arctic Grade
- Instrumentation Cable
- Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
- Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
- Pair / Triple / Quad twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs / Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs / Triples are identified by numbers printed directly on the insulated conductors.
- Inner covering: (F) Flame retardant an halogen-free thermoset compound
- Tape over inner covering: PET-tape
- Armour / screen: (O) Tinned annealed copper wire braid
- Tape over armour / screen: Rubberized Polyamide tape
- Outer sheath: (U) Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360)
- Outer sheath colour: Grey or Blue
|
Application/ Use:
- Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas.
- For installation in areas exposed to MUD and drilling / cleaning fluids.
- MeetS the OIL & MUD resistance requirement in NEK TS 606:2009.
- Meets the cold bend / cold impact requirement in CSA 22.2. 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at -40°C / -35°C.
|
Instrumentation Cables - RU / RFOU - Induvidual Shielded
|
RU(i) 150/250 (300)V S11 Unarmoured
- Instrumentation Cable
- Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
- Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
- Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbered tape or by numbers directly on the insulated conductors.
- Lay up / Shielding: Individually shielded pairs / triples / quads are laid up in concentric layers and wrapped with a PETP tape.
- Inner covering: No inner covering. (Additional tapes may be applied)
- Armour / Screen: No armour.
- Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
- Outer sheath colour: Grey or Blue
|
Application/ Use:
- Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas.
- Meets the mud resistant requirements in NEK TS 606:2009.
|
RFOU(i) 150/250 (300)V S1/S5
- Instrumentation Cable
- Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
- Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
- Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/ triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbered tape or numbers printed directly on the insulated conductors.
- Lay up / Shielding: Individually shielded pairs / triples / quads are laid up in concentric layers and wrapped with PETP tape.
- Inner covering: (F) Flame retardant and halogen-free thermoset compound
- Tape over inner covering: PET-tape
- Armour / screen: (O) Tinned annealed copper wire braid
- Tape over armour / screen: PET tape
- Outer sheath: (U) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
- Outer sheath colour: Grey or Blue
|
Application/ Use:
- Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 0,1 & 2) and safe areas.
- Meets the mud resistant requirements in NEK TS 606:2009
|
RFOU(i) 250V S1/S5 Arctic Grade
- Instrumentation Cable
- Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 Class2
- Insulation: (R) EP-rubber, IEC 60092-360 (EPR)
- Pair / Triple / Quad twisting: Color coded cores twisted together. Pairs / Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair / triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs / triples. Pairs / triples are identified by numbers printed directly on the insulated conductors.
- Lay up / Shielding: Individually shielded pairs / triples are laid up in concentric layers and wrapped with a PETP tape.
- Inner covering: (F) Flame retardant and halogen-free thermoset compound
- Tape over inner covering: PET-tape
- Armour/ screen: (O) Tinned annealed copper wire braid
- Tape over armour / screen: Rubberized Polyamide tape
- Outer sheath: (U) Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360)
- Outer sheath colour: Grey or Blue
|
Application/ Use:
- Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas.
- For installation in areas exposed to MUD and drilling / cleaning fluids.
- Meets the OIL & MUD resistance requirement in NEK TS 606:2009
- Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at -40°C / -35°C.
|